BS EN ISO 10563 Sealant Volume Change

Mechanical

ISO, BSI, EN

Sealants, Plastics, Chemical

Sealant is put into metal rings, the mass measured and the volume calculated. They are then left to cure for 28 days at 23±2°C and 50±5% RH, following which they are subjected to 70±2°C dry heat for 7 days and brought back down to 23±2°C for another day. Once all the conditioning is done they are weighed again and the new volume calculated, these results are compared to the first set of measurements and the amount of mass and volume lost is calculated.

 3,461 Views

Reviews From Our Happy Clients
4ward Testing have worked closely with Canusa and our client on all aspects of the work undertaken. Their wide experience, coupled with an in-depth knowledge of international specifications and standards, has helped speed the testing process considerably and their professional, authoritative and confident testing skills have allowed us to arrange witnessed tests, giving our clients even greater assurance of true independence - tangible benefits of the 4ward Testing philosophy of intelligent testing.We would have no hesitation in recommending 4ward Testing, as they have proven to be a modern, professional an progressive testing laboratory with a refreshing mix of academic and...