BS EN ISO 10563 Sealant Volume Change

Mechanical

ISO, BSI, EN

Sealants, Plastics, Chemical

Sealant is put into metal rings, the mass measured and the volume calculated. They are then left to cure for 28 days at 23±2°C and 50±5% RH, following which they are subjected to 70±2°C dry heat for 7 days and brought back down to 23±2°C for another day. Once all the conditioning is done they are weighed again and the new volume calculated, these results are compared to the first set of measurements and the amount of mass and volume lost is calculated.

 3,398 Views

Reviews From Our Happy Clients
We have been really satisfied with the high level of service, courtesy and clarity with which we have been helped in understanding the necessary requirements for the CE Marking of our products. The difference in approach between 4ward Testing and other European Test Laboratories has been huge

NPT Sealant and Bonding Solutions

image shows 4ward testing icon in white

Contact us today and discover how we add value to our clients

Let's work together to discover your true business advantages
Reviews From Our Happy Clients
We asked 4 Ward Testing to carry out testing on a construction industry material that was not easy to handle , to help us achieve CE Marking approval . The organisation did this without complaint and along with the after service care , we are pleased to use them again for future testing and projects.