This test involves applying sealants to moulds, allowing them to set and measuring the resulting surface. A set of sealant samples are put in a mould at 5±2°C and left horizontal to set, The thickness is then measured with a micrometer at several points and the flatness assessed. Anther set is put into moulds at 23±2°C with a faint slope and again allowed to set and measured.