Rubber, vulcanized or thermoplastic. Determination of compression set at ambient or elevated temperatures. A test piece of known thickness is compressed at standard laboratory temperature to a defined strain, which is then maintained constant for a specified time at standard laboratory temperature or a fixed elevated temperature. The compression is released and, after the test piece has been allowed to recover at a standard laboratory temperature or the elevated temperature for a specified time, the thickness of the test piece is again measured.